Find help with air conditioning around Caroline Springs and nearby suburbs.

Ducted reverse cycle replacement

Replacing gas ducted heating or an evaporative cooler with ducted reverse cycle in Caroline Springs: duct checks, zoning, discounts, licences and price ranges.

Ducted reverse cycle replaces a gas ducted heater, an evaporative cooler or both with one heat pump system that heats and cools through ceiling outlets. A basic supplied and installed system in Melbourne is published at $8,400 to $14,700, rising to $12,600 to $23,100 for premium or zoned systems, and the condition of the existing ducts often decides where in that band a job lands.

Illustrative photo for Ducted reverse cycle replacement

The work is quoted and done by independent licensed providers. This website collects the enquiry and refers it.

Why owners in Caroline Springs look at this upgrade

The council’s community profile records that significant residential development in the eastern part of the City of Melton began in the mid 1990s, creating suburbs such as Burnside, Caroline Springs and Hillside, with Taylors Hill following. Houses from that period that still run their first gas ducted heater or roof-mounted evaporative unit are now old enough that owners start weighing a repair against a full change. Typical triggers include:

  • the gas heater has failed a service or keeps locking out
  • the evaporative cooler leaks, smells musty or cannot keep up on muggy days
  • the owner wants refrigerated cooling that works with windows closed
  • the owner is moving away from gas appliances
  • a rental property must meet efficient heating and cooling standards

Ducted options compared

Option Heats Cools Main trade-off
Keep gas ducted heating, add splits Yes, gas Rooms with splits only Two systems to maintain
Ducted reverse cycle, reuse some ducts Yes Yes Old heating ducts may be too small or poorly insulated for cooling
Ducted reverse cycle, new ductwork Yes Yes Highest cost, best result
Replace gas ducted heater like for like Yes, gas No Keeps gas running costs and the servicing obligation
Multi-split system Yes Yes No roof ducts, one indoor head per room

Published Melbourne figures for comparison: a gas ducted heater supplied and installed runs $4,000 to $11,550, a multi-split with two indoor heads $4,200 to $7,900, and whole-house ductwork replacement $2,000 to $6,300. All figures come from a Melbourne metro guide updated October 2026 and include GST.

Can my existing heating ducts be reused?

Sometimes, but a careful provider will not assume it. The YourHome guide to heating and cooling says ducts need to be larger if they are also used for cooling, that ducted air conditioning ducts must be insulated to at least R1.5 with sealed joints to stop condensation and leakage, and that duct runs should be straight with tightly taped joints. Ducts sized only for gas heating, especially older flexible ducts that have sagged or split in the roof, often fail on one of those points.

Floor vents are another issue. Some gas ducted systems deliver warm air through floor registers. Reverse cycle ducted systems are normally fitted with ceiling outlets because cool air falls, so a conversion can mean new outlets in every room and patching the old floor vents.

What a provider will check before quoting

  • Roof space access, height and whether there is room for the indoor fan coil unit on platforms between trusses.
  • The heat load of each room, including west-facing glass and the floor area of any upstairs rooms.
  • The size, insulation and condition of existing ducts and outlets.
  • Where the outdoor unit can sit with clearance for airflow and servicing, and how far it is from bedroom windows.
  • Switchboard capacity and whether the supply can carry the new load.
  • How the old gas heater will be disconnected and capped, and how the old evaporative unit will be removed and the roof opening sealed.
  • How many zones you want, for example living areas and bedrooms on separate controls.

YourHome notes that zoned systems condition only the occupied areas and let living and sleeping areas be controlled separately, which reduces energy use.

What the job involves

  1. Remove the old gas furnace, cap the gas line and make the flue safe, which is gasfitting work.
  2. Remove the evaporative cooler if there is one, then seal and weatherproof the roof opening.
  3. Install the fan coil unit in the roof, the outdoor unit on a slab or brackets and the refrigerant pipework between them.
  4. Install or modify ductwork, ceiling outlets, a return air grille and zone motors.
  5. Run the electrical supply and controls, then pressure test, evacuate and commission the system.
  6. Hand over the plumbing compliance certificate, the electrical certificate and the warranty details.

Which rules and licences apply?

The Building and Plumbing Commission describes refrigerated air-conditioning work under Part 4 of the Plumbing Regulations 2018 as covering the installation, replacement and commissioning of refrigerated air-conditioning equipment such as fan coil units, together with any ductwork, roof sheeting and roof flashing needed for that work. Duct fixing has its own restricted class. Disconnecting a gas heater is gasfitting work and needs a practitioner licensed in that class. The BPC requires a compliance certificate when work exceeds its value threshold, and always for the installation, relocation or replacement of a Type A gas appliance. The electrician issues a Certificate of Electrical Safety for the wiring.

Refrigerant work also needs a refrigerant handling licence from the Australian Refrigeration Council.

Discounts for replacing a ducted gas heater

The Victorian Energy Upgrades program lists its larger household discounts for removing or replacing a ducted gas heater with an efficient reverse cycle system. Conditions on the program page include an approved high efficiency product, a minimum five year warranty for homes, and a replaced system that is more than two years old. Contact an accredited provider before you buy, because the program says retrospective discounts are typically not possible. Read the current amounts on the Victorian Energy Upgrades heating and cooling discounts page.

Landlords should note the same page: from 1 March 2027, a space heater in a rental home that breaks and cannot be repaired must be replaced with an efficient reverse cycle air conditioner with an outlet in the main living area.

Red flags in a ducted quote

  • A kilowatt figure with no room-by-room heat load.
  • “Reuse existing ducts” with no inspection of the roof space.
  • No line item for capping the gas or removing the old evaporative unit.
  • No mention of zoning, outlet positions or the return air grille.
  • No mention of who issues the plumbing and electrical certificates.

What to do next

Count your rooms and current vents, note whether outlets are in the floor or ceiling, and photograph the heater badge in the roof or under the house. Then ask for a ducted reverse cycle quote. For the gas system you already have, the ducted heating service page explains what a safety service covers. If you also run an evaporative cooler, see evaporative cooling service, and compare the whole picture in the Caroline Springs air conditioning cost guide.

Send a job enquiry

Frequently asked questions

Can I keep my gas cooktop and hot water if the gas heater goes?

Yes. Removing the ducted heater affects that appliance only. The gasfitter disconnects it and caps its supply, and other gas appliances stay connected. Whether to close the gas account later is a separate decision.

Can I keep the evaporative cooler and add ducted reverse cycle?

It can be done, but you then maintain two ducted systems with two sets of ceiling outlets, and the cooler still needs sealing each winter. Ask the provider to price both options: keeping the cooler, and removing it with the roof opening sealed.

Can I get a ducted price without a site visit?

A careful provider will want to see the roof space, the existing ducts, the switchboard and where the outdoor unit could sit before committing to a price. A rough phone figure is a starting point at best.

How many zones should a ducted system have?

Most homes split living areas from bedrooms at a minimum. Two storey homes often add an upstairs zone. More zones cost more, so match them to how the household actually uses the house.

Who removes the old gas heater?

A licensed gasfitter disconnects the heater and caps the gas line. Ask the ducted installer whether that is part of their quote or whether you need to book it separately.